CG1BN50-125Z 日本smc
1) Use tubing with no flaws on its periphery and cut it off at a
right angle. When cutting the tubing, use a tube cutter,
TK-1, 2 or 3. Do not use pinchers, nippers or scissors, etc.
If cutting is done with tools other than tube cutters, the
tubing may be cut diagonally or become flattened, etc.
This can make a secure installation impossible, and cause
problems such as the tubing pulling out after installation or
air leakage. Allow some extra length in the tubing.
(2) The outside diameter of the polyurethane tubing swells
when internal pressure is applied to it. Therefore, it may
not be possible that the tubing can be re-inserted into
the one-touch fitting. Confirm the tubing outside diameter,
and when the accuracy of the outside diameter is
+0.15 or larger, re-insert the tubing into the one-touch
fitting without cutting it. When the tubing is re-inserted
into the one-touch fitting, confirm that the tubing goes
through the release button smoothly.
(3) Grasp the tubing and push it in slowly, inserting it securely
all the way into the fitting.
(4) After inserting the tubing, pull on it lightly to confirm that
it will not come out. If it is not installed securely all the
way into the fitting, this can cause problems such as air
leakage or the tubing pulling out.
2) Removal of tubing
(1) Push in the release button sufficiently. When doing this,
push the collar evenly.
(2) Pull out the tubing while holding down the release button
so that it does not come out. If the release button is not
pressed down sufficiently, there will be increased bite on
the tubing and it will become more difficult to pull it out.
(3) When the removed tubing is to be used again, cut off
the portion which has been chewed before reusing it. If
the chewed portion of the tubing is used as it is, this can
cause trouble such as air leakage or difficulty in removing
the tubing.
2. Do not install the SMC’s KQ one-touch fitting series with a
metal rod into the ZFC05/10 series fittings. The metal rod will
not be held and the fitting will shoot out.
Caution
1. When tubing of brands other than SMC’s are used, verify that
the tubing O.D. satisfies the following accuracy;
1) Nylon tubing : Within ±0.1 mm
2) Soft nylon tubing : Within ±0.1 mm
3) Polyurethane tubing: Within +0.15 mm, within –0.2 mm
Do not use tubing which does not meet these outside diameter
tolerances.
It may not be possible to connect them, or they may cause
other trouble, such as air leakage or the tube pulling out after
connection.
2. Tubing O.D: ?2
Other tube brands cannot be used. It may not be possible to
connect them, or they may cause other trouble, such as air
leakage or the tube pulling out after connection.
021-39526589
網(wǎng)址:www.wiua.cn
地 址:上海市嘉定區(qū)嘉涌路99弄
6號(hào)樓713室